Search results for "correction [final-state interaction]"
showing 10 items of 57 documents
Determination of critical eluent composition for polyethylenglycols using on-line liquid chromatography-Fourier transform infrared spectrometry.
2008
In this work, it has been extended to methanol:water mobile phases, the use of a background correction method for on-line LC-FTIR measurements named Univariate background correction based on the use of a reference spectra matrix (UBC-RSM) and absorbance ratios. It permits to overcome the problem related to spectral changes occurring during the gradient elution, which in the past limited the on-line coupling of LC and FTIR to isocratic elutions. The combined use of the aforementioned background correction technique in on-line isocratic and gradient LC-FTIR, and partial least squares (PLS) has been applied for the search of the critical conditions for polymers. Polyethylenglycol (PEG) has bee…
Investigating Aid Effectiveness in Developing Countries: The Case of Nepal
2020
Foreign aid serves as an important source of capital for any developing or under-developed country. It is very important to see how the recipient country can utilize this aid in the economic upliftment of the nation. Taking a case of Nepalese economy, this paper investigates the effectiveness of foreign aid in developing countries. The result from Johansen’s cointegration test reveals that foreign aid independently is not adequate for the economic growth. Increased capital and technological infrastructures, improved skills on human capital, on the other hand, significantly changes the result for the positive aid impact on growth in the long run. Therefore, we can conclude that a good policy…
Dye-tracer technique for rill flows by velocity profile measurements
2020
Abstract Water flow on hillslope soil surface supplies energy which is required to detach soil particles, to transport and deposit sediments, therefore flow velocity is a key variable related to hillslope hydrodinamics of soil erosion processes. Among the different methods available for measuring velocity of shallow interrill and rill flow, the trace technique is widely used. Trace technique is applied by adding a material (salt, magnetic material, water isotope, floating object) and then measuring the speed of the material to travel a known distance from the injection point. When flow velocity is measured using a dye-tracing method, the mean velocity is calculated by multiplying the measur…
Flume experiments for assessing the dye-tracing technique in rill flows
2021
Abstract Flow velocity controls hillslope soil erosion and is a key hydrodynamic variable involved in sediment transport and deposition processes. The dye-tracer technique is one of the most applied methods for measuring velocity of shallow interrill and rill flow. The technique is based on the injection of a tracer in a specific point and the measurement of its speed to travel the known distance from the injection point to a given channel section. The dye-tracer technique requires that the measured surface flow velocity has to be corrected to obtain the mean flow velocity using a correction factor which is generally empirically deduced. The technique has two sources of uncertainties: i) th…
Climate signals in δ13C of wood lignin methoxyl groups from high-elevation larch trees
2016
Abstract In this study, a barely used method to measure δ13C values from lignin methoxyl groups (δ13Cmethoxyl) of tree‐rings is applied to high alpine larch trees to test their potential as a climate proxy. Thirty-seven larch trees (Larix decidua Mill.) were sampled at a tree line site near Simplon Village in the Valais/Switzerland. Samples were used to measure tree-ring width, and from five individuals, δ13Cmethoxyl was determined at annual resolution from 1971 to 2009, and at pentadal resolution from 1747 to 2009. The physiological tree responses to increasing atmospheric CO2 concentration since 1850 and the corresponding decrease in δ13C (Suess effect) were corrected using a range of pub…
Example of a technique for evaluation of interferences caused by complicated sample matrix elements in ICP-AES determination
2001
An example of a useful and rapid procedure for the evaluation of interferences caused by complicated sample matrices in inductively coupled plasma atomic emission spectrometry (ICP-AES) is described. Using simple acid-base standards, all the elements investigated were determined separately in complicated matrices with satisfactory results. Multiple linear regression was used to calculate the linear correction coefficients for each matrix element analyzed. Good analytical results improved still further when this correction method was used.
Possible learning and reading disorder nonmedication correction methods
2011
Nomofilachia e correzione di ufficio delle sentenze della Cassazione
2020
La Corte di cassazione è l’organo di vertice dell’ordinamento giudiziario civile e penale italiano, come giudice di legittimità di ultimo grado. Lo scritto esamina i profili problematici della funzione della Corte di cassazione civile, che ha assegnato a se stessa il ruolo di guida della giurisprudenza e ha messo in secondo piano la funzione di garanzia dei diritti delle parti. La evoluzione del ruolo della Corte di cassazione ha recentemente determinato un uso improprio del procedimento di correzione, che è diretto ad emendare errori materiali o di calcolo. In particolare, la Corte di cassazione ha affermato di avere il potere di promuovere di ufficio il procedimento di correzione per emen…
Corrected whole blood biomarkers : the equation of Dill and Costill revisited
2018
An exercise bout or a dehydration often causes a reduction in plasma volume, which should be acknowledged when considering the change in biomarkers before and after the plasma changing event. The classic equation from Dill and Costill (1974, J. Appl. Physiol., 37, 247–248) for plasma volume shift is usually utilized in such a case. Although this works well with plasma and serum biomarkers, we argue in this note that this traditional approach gives misleading results in the context of whole blood biomarkers, such as lactate, white cells, and thrombocytes. In this study, we demonstrate that to calculate the change in the total amount of circulating whole blood biomarker, one should utilize a …
On the size of transducers for bidirectional decoding of prefix codes
2012
In a previous paper [L. Giambruno and S. Mantaci, Theoret. Comput. Sci. 411 (2010) 1785–1792] a bideterministic transducer is defined for the bidirectional deciphering of words by the method introduced by Girod [ IEEE Commun. Lett. 3 (1999) 245–247]. Such a method is defined using prefix codes. Moreover a coding method, inspired by the Girod’s one, is introduced, and a transducer that allows both right-to-left and left-to-right decoding by this method is defined. It is proved also that this transducer is minimal. Here we consider the number of states of such a transducer, related to some features of the considered prefix code X . We find some bounds of such a number of states in relation wi…